1,968 research outputs found

    Comparison between high-energy proton and charged pion induced damage in Lead Tungstate calorimeter crystals

    Full text link
    A Lead Tungstate crystal produced for the electromagnetic calorimeter of the CMS experiment at the LHC was cut into three equal-length sections. The central one was irradiated with 290 MeV/c positive pions up to a fluence of (5.67 +- 0.46)x10^13 /cm^2, while the other two were exposed to a 24 GeV/c proton fluence of (1.17 +- 0.11) x 10^13/ cm^2. The damage recovery in these crystals, stored in the dark at room temperature, has been followed over two years. The comparison of the radiation-induced changes in light transmission for these crystals shows that damage is proportional to the star densities produced by the irradiation.Comment: 7 pages, 4 figure

    Detection of Cherenkov light from air showers with Geiger-APDs

    Full text link
    We have detected Cherenkov light from air showers with Geiger-mode APDs (G-APDs). G-APDs are novel semiconductor photon-detectors, which offer several advantages compared to conventional photomultiplier tubes in the field of ground-based gamma-ray astronomy. In a field test with the MAGIC telescope we have tested the efficiency of a G-APD / light catcher setup to detect Cherenkov light from air showers. We estimate a detection efficiency, which is 60% higher than the efficiency of a MAGIC camera pixel. Ambient temperature dark count rates of the tested G-APDs are below the rates of the night sky light background. According to these recent tests G-APDs promise a major progress in ground-based gamma-ray astronomy.Comment: 4 pages, 5 figures, to appear in the proceedings of the 30th International Cosmic Ray Conference, Merida, July 200

    Infrared scintillation yield in gaseous and liquid argon

    Full text link
    The study of primary and secondary scintillations in noble gases and liquids is of paramount importance to rare-event experiments using noble gas media. In the present work, the scintillation yield in gaseous and liquid Ar has for the first time been measured in the near infrared (NIR) and visible region, both for primary and secondary (proportional) scintillations, using Geiger-mode avalanche photodiodes (G-APDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast component was measured to be 17000 photon/MeV in gaseous Ar in the NIR, in the range of 690-1000 nm, and 510 photon/MeV in liquid Ar, in the range of 400-1000 nm. Proportional NIR scintillations (electroluminescence) in gaseous Ar have been also observed; their amplification parameter at 163 K was measured to be 13 photons per drifting electron per kV. Possible applications of NIR scintillations in high energy physics experiments are discussed.Comment: 6 pages, 5 figures. Submitted to Europhysics Letter. Revised Figs. 3 and

    Non-adiabatic effects in the phonon dispersion of Mg 1--x Al x B 2

    Full text link
    Superconducting MgB_2\_2 shows an E_2g\_{2g} zone center phonon, as measured by Raman spectroscopy, that is very broad in energy and temperature dependent. The Raman shift and lifetime show large differences with the values elsewhere in the Brillouin Zone measured by Inelastic X-ray Scattering (IXS), where its dispersion can be accounted for by standard harmonic phonon theory, adding only a moderate electron-phonon coupling. Here we show that the effects rapidly disappear when electron-phonon coupling is switched off by Al substitution on the Mg sites. Moreover, using IXS with very high wave-vector resolution in MgB_2\_2, we can follow the dispersion connecting the Raman and the IXS signal, in agreement with a theory using only electron-phonon coupling but without strong anharmonic terms. The observation is important in order to understand the effects of electron-phonon coupling on zone center phonons modes in MgB_2\_2, but also in all metals characterized by a small Fermi velocity in a particular direction, typical for layered compounds

    Light response of pure CsI calorimeter crystals painted with wavelength-shifting lacquer

    Get PDF
    We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted with a special wavelength-shifting solution were examined in a custom-build detection apparatus (RASTA=radioactive source tomography apparatus) that uses a 137Cs radioactive gamma source, cosmic muons and a light emitting diode as complementary probes of the scintillator light response. We have extracted the total light output, axial light collection nonuniformities and timing responses of the individual CsI crystals. These results predict improved performance of the 3 pi sr PIBETA calorimeter due to the painted lateral surfaces of 240 CsI crystals. The wavelength-shifting paint treatment did not affect appreciably the total light output and timing resolution of our crystal sample. The predicted energy resolution for positrons and photons in the energy range of 10-100 MeV was nevertheless improved due to the more favorable axial light collection probability variation. We have compared simulated calorimeter ADC spectra due to 70 MeV positrons and photons with a Monte Carlo calculation of an ideal detector light response.Comment: Elsevier LaTeX, 35 pages in e-print format, 15 Postscript Figures and 4 Tables, also available at http://pibeta.phys.virginia.edu/~pibeta/subprojects/csipro/tomo/rasta.p

    A novel camera type for very high energy gamma-ray astronomy based on Geiger-mode avalanche photodiodes

    Full text link
    Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light detection in atmospheric Cherenkov telescopes. In this paper, the design and commissioning of a 36-pixel G-APD prototype camera is presented. The data acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond time resolution has been achieved. Cosmic-ray induced air showers have been recorded using an imaging mirror setup, in a self-triggered mode. This is the first time that such measurements have been carried out with a complete G-APD camera.Comment: 9 pages with 11 figure

    Scintillation counter with MRS APD light readout

    Full text link
    START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.Comment: 6 pages, 5 figure

    On the low-temperature performances of THGEM and THGEM/G-APD multipliers in gaseous and two-phase Xe

    Full text link
    The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier was demonstrated in two-phase Xe with gains reaching 600. These are compared to existing data, summarized here for two-phase Ar, Kr and Xe avalanche detectors incorporating GEM and THGEM multipliers. The optical readout of THGEMs with Geiger-mode Avalanche Photodiodes (G-APDs) has been investigated in gaseous Xe at cryogenic temperature; avalanche scintillations were recorded in the Near Infrared (NIR) at wavelengths of up to 950 nm. At avalanche charge gain of 350, the double-THGEM/G-APD multiplier yielded 0.07 photoelectrons per initial ionization electron, corresponding to an avalanche scintillation yield of 0.7 NIR photons per avalanche electron over 4pi. The results are compared with those of two-phase Ar avalanche detectors. The advantages, limitations and possible applications are discussed.Comment: 22 pages, 14 figures. Revised Figs. 10,11 and Table 1. To be published in JINS

    Lattice dynamics and electron-phonon coupling in transition metal diborides

    Full text link
    The phonon density-of-states of transition metal diborides TMB2 with TM = Ti, V, Ta, Nb and Y has been measured using the technique of inelastic neutron scattering. The experimental data are compared with ab initio density functional calculations whereby an excellent agreement is registered. The calculations thus can be used to obtain electron-phonon spectral functions within the isotropic limit. A comparison to similar data for MgB2 and AlB2 which were subject of prior publications as well as parameters important for the superconducting properties are part of the discussion.Comment: 4 pages, 3 figure
    • …
    corecore